Instruments

Mass flowmeter used for viscous or shear-sensitive products, products requiring low flow velocities, non-homogeneous mixtures, products with entrained solids or gas, custody transfer, loading and product transfer measurement, slurries, and highly corrosive fluids.
Coriolis Mass Flow Sensor VM9080 Optimass 7000
Mass flowmeter used for viscous or shear-sensitive products, products requiring low flow velocities, non-homogeneous mixtures, products with entrained solids or gas, custody transfer, loading and product transfer measurement, slurries, and highly corrosive fluids.
Mass flow signal converter for combination with Coriolis mass flow sensor Optimass 7000 from Krohne.
Coriolis Signal Converter MFC 400
Mass flow signal converter for combination with Coriolis mass flow sensor Optimass 7000 from Krohne.
<p>Pipe sensor for flow measurement with very high accuracy in  slight to heavily polluted media. For installation in pipes up to 5000  mm diameter.         </p>
Cross Correlation Pipe Sensor CS2

Pipe sensor for flow measurement with very high accuracy in slight to heavily polluted media. For installation in pipes up to 5000 mm diameter.

<p>Pipe sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels up to DN 1000 with low levels.<br /></p>
Cross Correlation Pipe Sensor CSM V100R

Pipe sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels up to DN 1000 with low levels.

<p>           Pipe sensor for flow velocity and level  detection in part filled and full pipes and channels. For installation  in pipes.          </p>
Cross Correlation Pipe Sensor POA

Pipe sensor for flow velocity and level detection in part filled and full pipes and channels. For installation in pipes.

High accurate flow measurement system for continuous measurement of slight to heavily polluted water in filled pipes.
Cross Correlation Transmitter NivuFlow 700
High accurate flow measurement system for continuous measurement of slight to heavily polluted water in filled pipes.
Flowmeter designed for temporary  flow measurement over long- term periods in open channel applications  such as wastewater collection systems, storm sewer systems, and combined sewer systems.
Cross Correlation Transmitter VM9902 PCM 4
Flowmeter designed for temporary flow measurement over long- term periods in open channel applications such as wastewater collection systems, storm sewer systems, and combined sewer systems.
The NFP has been developed particularly for flow measurement in full pipes with diameters between 100-800 mm. Based on the cross correlation method, the system can be used in a range of slightly to heavily polluted media.
Cross Correlation Transmitter VM9903 NFP
The NFP has been developed particularly for flow measurement in full pipes with diameters between 100-800 mm. Based on the cross correlation method, the system can be used in a range of slightly to heavily polluted media.
High accurate flow measurement for slightly polluted and dirty media in part filled and full pipes, channels and more.
Cross Correlation Transmitter VM9904 NivuFlow 750
High accurate flow measurement for slightly polluted and dirty media in part filled and full pipes, channels and more.
For high accurate and portable measurement in part filled and full channels. Best use for wastewater applications.
Cross Correlation Transmitter VM9908 NivuFlow Mobile 750
For high accurate and portable measurement in part filled and full channels. Best use for wastewater applications.
<p>Wedge sensor for flow measurement with very high accuracy in  slight to heavily polluted media. For installation on channel wall or  channel bottom.         </p>
Cross Correlation Wedge Sensor CS2

Wedge sensor for flow measurement with very high accuracy in slight to heavily polluted media. For installation on channel wall or channel bottom.

<p>Wedge sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels up to DN 500 with low levels.<br /></p>
Cross Correlation Wedge Sensor CSM V100K

Wedge sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels up to DN 500 with low levels.

<p>Wedge sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels up to DN 500 with low levels.<br /></p>
Cross Correlation Wedge Sensor CSM V1D0

Wedge sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels up to DN 500 with low levels.

<p>Wedge sensor for flow measurement of slight to heavily polluted media in  filled or partially filled pipes and channels in large dimensions.</p>
Cross Correlation Wedge Sensor CSP

Wedge sensor for flow measurement of slight to heavily polluted media in filled or partially filled pipes and channels in large dimensions.

<p>           Wedge sensor for flow measurement with very high accuracy in  slight to heavily polluted media. For installation on channel wall or  channel bottom.</p>
Cross Correlation Wedge Sensor POA V200K

Wedge sensor for flow measurement with very high accuracy in slight to heavily polluted media. For installation on channel wall or channel bottom.

<p>           Wedge sensor for flow measurement with very high accuracy in  slight to heavily polluted media. For installation on channel wall or  channel bottom         </p>
Cross Correlation Wedge Sensor POA V2H1K

Wedge sensor for flow measurement with very high accuracy in slight to heavily polluted media. For installation on channel wall or channel bottom

Compact GPRS data logger with 4 inputs. Compact construction with integrated battery compartment. Switchable sensor supply voltage. Built-in measurement value memory, 177 days capacity, protection IP 66.
Data Logger NivuLog Easy
Compact GPRS data logger with 4 inputs. Compact construction with integrated battery compartment. Switchable sensor supply voltage. Built-in measurement value memory, 177 days capacity, protection IP 66.
Doppler sensor for flow measurement in slight to heavily polluted media. Designed for fastening in pipes using a nozzle.
Doppler Pipe Sensor KDA
Doppler sensor for flow measurement in slight to heavily polluted media. Designed for fastening in pipes using a nozzle.
Flow metering system, utilizes a full bidirectional ultrasonic velocity sensor. Level measurement can be carried out either by a sensor-integrated pressure cell or by using an external sensor.
Doppler Signal Converter VM9905 OCM F
Flow metering system, utilizes a full bidirectional ultrasonic velocity sensor. Level measurement can be carried out either by a sensor-integrated pressure cell or by using an external sensor.
Flowmeter with a large back-lit display that enables very comfortable transmitter operation. Parameters can be set very easy due  to intuitive dialog mode menus. Measured and logged data is saved on plug-in CF memory card.
Doppler Signal Converter VM9906 PCM F
Flowmeter with a large back-lit display that enables very comfortable transmitter operation. Parameters can be set very easy due to intuitive dialog mode menus. Measured and logged data is saved on plug-in CF memory card.
Doppler sensor for flow measurement in slight to heavily polluted  media. Wedge shape for installation on channel wall or channel bottom.
Doppler Wedge Sensor KDA
Doppler sensor for flow measurement in slight to heavily polluted media. Wedge shape for installation on channel wall or channel bottom.
Electromagnetic flowmeter  in sandwich design. Easy to install. Affordable price. Maintenance free. Excellent chemical resistance.
Electromagnetic Flow Sensor VM9023 Optiflux 1000
Electromagnetic flowmeter  in sandwich design. Easy to install. Affordable price. Maintenance free. Excellent chemical resistance.
Electromagnetic flowmeter in flanged design. Easy to install. Maintenance free. Hastelloy electrodes. Long-term reliability and negligible maintenance.
Electromagnetic Flow Sensor VM9024 Optiflux 2000
Electromagnetic flowmeter in flanged design. Easy to install. Maintenance free. Hastelloy electrodes. Long-term reliability and negligible maintenance.
Electromagnetic flowmeter in flanged design. Easy to install. Maintenance free. Hastelloy electrodes. Long-term reliability and negligible maintenance.
Electromagnetic Flow Sensor VM9025 Optiflux 4000
Electromagnetic flowmeter in flanged design. Easy to install. Maintenance free. Hastelloy electrodes. Long-term reliability and negligible maintenance.
Electromagnetic flowmeter  in flanged design. Exceptional long-term stability and accuracy. For highly aggressive and abrasive fluids.
Electromagnetic Flow Sensor VM9026 Optiflux 5000
Electromagnetic flowmeter  in flanged design. Exceptional long-term stability and accuracy. For highly aggressive and abrasive fluids.
Electromagnetic flowmeter in flanged design. Easy to install.  Maintenance free. Long-term reliability and  negligible maintenance.
Electromagnetic Flow Sensor VM9028 Waterflux 3000
Electromagnetic flowmeter in flanged design. Easy to install. Maintenance free. Long-term reliability and negligible maintenance.
Electromagnetic flow converter for combination with Krohne OPTIFLUX and WATERFLUX flow sensors. Compact, remote field, wall-mounted and rack-mounted housing. With extensive diagnostics for advanced requirements (NE 107). 4-wire, 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET etc.
Electromagnetic Signal Converter VM9035 IFC 300
Electromagnetic flow converter for combination with Krohne OPTIFLUX and WATERFLUX flow sensors. Compact, remote field, wall-mounted and rack-mounted housing. With extensive diagnostics for advanced requirements (NE 107). 4-wire, 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET etc.
Electromagnetic flow converter for combination with Krohne OPTIFLUX and WATERFLUX flow sensors. Compact, remote field, wall-mounted and rack-mounted housing. With extensive diagnostics for advanced requirements (NE 107). 4-wire, 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET etc.
Electromagnetic Signal Converter VM9037 IFC 100
Electromagnetic flow converter for combination with Krohne OPTIFLUX and WATERFLUX flow sensors. Compact, remote field, wall-mounted and rack-mounted housing. With extensive diagnostics for advanced requirements (NE 107). 4-wire, 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET etc.
Electromagnetic flow converter for combination with Krohne flow sensors.
Electromagnetic Signal Converter VM9038 IFC 070
Electromagnetic flow converter for combination with Krohne flow sensors.
Electromagnetic flow converter for combination with Krohne flow sensors.
Electromagnetic Signal Converter VM9039 IFC 050
Electromagnetic flow converter for combination with Krohne flow sensors.
Electronic box for connection of passive sensors to permanent flow meters.
Electronic Box EBM
Electronic box for connection of passive sensors to permanent flow meters.
Vibration level switch for liquids. Designed for use in all liquids. Output options: relay, transistor, NAMUR, contactless electronic switch and 2-wire. Repeatability: +/- 2 mm.
Level Switch VM9840 Optiswitch 4000
Vibration level switch for liquids. Designed for use in all liquids. Output options: relay, transistor, NAMUR, contactless electronic switch and 2-wire. Repeatability: +/- 2 mm.
Vibration level switch for liquids. Designed for use in all liquids. Output options: relay, transistor, NAMUR, contactless electronic switch and 2-wire. Repeatability: +/- mm.
Level Switch VM9841 Optiswitch 5100
Vibration level switch for liquids. Designed for use in all liquids. Output options: relay, transistor, NAMUR, contactless electronic switch and 2-wire. Repeatability: +/- mm.
Vibration level switch for liquids. Designed for use in all liquids. Output options: relay, transistor, NAMUR, contactless electronic switch and 2-wire. Repeatability: +/- 2 mm.
Level Switch VM9842 Optiswitch 5200
Vibration level switch for liquids. Designed for use in all liquids. Output options: relay, transistor, NAMUR, contactless electronic switch and 2-wire. Repeatability: +/- 2 mm.
Consol with cut out holes for easy mounting of level sensors and level meters from Pulsar.
Mounting Console for Level Sensors and Level Meters
Consol with cut out holes for easy mounting of level sensors and level meters from Pulsar.
Multiplexer for NivuFlow 750 type M9.
Multiplexer MPX
Multiplexer for NivuFlow 750 type M9.
Oval wheel meter developed for the measurement or control of small flows and quantities in a process or in the laboratory. The typical materials to be measured are lubricating oil, hydraulic oil, and diesel in power generators, burners, motors, and oil circulation systems.
Oval Wheel Meter VM9050
Oval wheel meter developed for the measurement or control of small flows and quantities in a process or in the laboratory. The typical materials to be measured are lubricating oil, hydraulic oil, and diesel in power generators, burners, motors, and oil circulation systems.
Oval wheel meter developed for the measurement or control of small flows  and quantities in a process or in the laboratory. The typical materials  to be measured are lubricating oil, hydraulic oil, and diesel in power  generators, burners, motors, and oil circulation systems.
Oval Wheel Meter VM9051
Oval wheel meter developed for the measurement or control of small flows and quantities in a process or in the laboratory. The typical materials to be measured are lubricating oil, hydraulic oil, and diesel in power generators, burners, motors, and oil circulation systems.
Oval wheel meter developed for the measurement or control of small flows and quantities in a process or in the laboratory. The typical materials to be measured are lubricating oil, hydraulic oil, and diesel in power generators, burners, motors, and oil circulation systems.
Oval Wheel Meter VM9052
Oval wheel meter developed for the measurement or control of small flows and quantities in a process or in the laboratory. The typical materials to be measured are lubricating oil, hydraulic oil, and diesel in power generators, burners, motors, and oil circulation systems.
Oval wheel meter developed for the measurement or control of small flows  and quantities in a process or in the laboratory. The typical materials  to be measured are lubricating oil, hydraulic oil, and diesel in power  generators, burners, motors, and oil circulation systems.
Oval Wheel Meter VM9053
Oval wheel meter developed for the measurement or control of small flows and quantities in a process or in the laboratory. The typical materials to be measured are lubricating oil, hydraulic oil, and diesel in power generators, burners, motors, and oil circulation systems.
Pressure gauge, non liquid filled, for air, non aggressive liquids, and gases in industrial applications and HVAC applications. Big window to ensure good reading from a distance also.
Pressure Gauge VM9701
Pressure gauge, non liquid filled, for air, non aggressive liquids, and gases in industrial applications and HVAC applications. Big window to ensure good reading from a distance also.
Pressure gauge, liquid filled, for air, non aggressive liquids, and gases in industrial applications and HVAC applications where pressure shocks and vibrations may occur. Big window to ensure good reading from a distance also.
Pressure Gauge VM9706
Pressure gauge, liquid filled, for air, non aggressive liquids, and gases in industrial applications and HVAC applications where pressure shocks and vibrations may occur. Big window to ensure good reading from a distance also.
Pressure gauge graded 0-10 bar.
Pressure Gauge VM9710
Pressure gauge graded 0-10 bar.
Level meter for measuring distance,  level, interface, level and interface, volume and mass. Higher  signal dynamics and a sharper pulse than conventional TDR devices and therefore better reproducibility and accuracy. Displays level and interface.
Radar Level Meter VM9850 Optiflex 1300 C
Level meter for measuring distance, level, interface, level and interface, volume and mass. Higher signal dynamics and a sharper pulse than conventional TDR devices and therefore better reproducibility and accuracy. Displays level and interface.
<p>Radar sensor for NivuFlow 550 från Nivus.</p>
Radar Sensor OFR

Radar sensor for NivuFlow 550 från Nivus.

Radar flow meter for part filled pipes, with low levels, and high flow volocity.
Radar Transmitter VM9907 NivuFlow 550
Radar flow meter for part filled pipes, with low levels, and high flow volocity.
<p>Non-contacting FMCW radar sensor for level and volume measurement. Is easily set-up with any Pulsar controller, whether you are interested in our cost-effective 2 relay Blackbox 130 for level, or our 5 relay Ultra 5 which can be set-up for level, volume, flow or pump control, or even our Ultimate Controller which has 8 relays standard but offers the ability to be expandable.<br /></p>
Sensor VM9818 dBR 16

Non-contacting FMCW radar sensor for level and volume measurement. Is easily set-up with any Pulsar controller, whether you are interested in our cost-effective 2 relay Blackbox 130 for level, or our 5 relay Ultra 5 which can be set-up for level, volume, flow or pump control, or even our Ultimate Controller which has 8 relays standard but offers the ability to be expandable.

Sludge Finder 2 is a proven effective sludge blanket interface monitor in both waste water and industrial applications. Sludge Finder 2  provides a continuous level indication. Operates ultrasonically through  liquids.
Sludge Controller VM9820 Sludge Finder 2
Sludge Finder 2 is a proven effective sludge blanket interface monitor in both waste water and industrial applications. Sludge Finder 2 provides a continuous level indication. Operates ultrasonically through liquids.
Ballhead sensor for measurement places with various geometries. For connection to NivuFlow 650 transmitters. High accurate flow measurement based on the transit time method for open channels and waters, mainly process water channels and natural water bodies. <br />
Ultrasonic Ballhead Sensor NOS V20BS
Ballhead sensor for measurement places with various geometries. For connection to NivuFlow 650 transmitters. High accurate flow measurement based on the transit time method for open channels and waters, mainly process water channels and natural water bodies.
<p>Clamp-on sensor for contactless flow measurement in pipes. Clamp-on ultrasonic flow meter is ideal for retrofitting system at flow measurement places as well as for monitoring of drinking water networks. Unaffected by pressure and temperature.<br /></p>
Ultrasonic Clamp-On Sensor NIC-C0O1

Clamp-on sensor for contactless flow measurement in pipes. Clamp-on ultrasonic flow meter is ideal for retrofitting system at flow measurement places as well as for monitoring of drinking water networks. Unaffected by pressure and temperature.

<p>Clamp-on sensor for contactless flow measurement in full pipes. Clamp-on ultrasonic flow meter is ideal for retrofitting system at flow measurement places as well as for monitoring of drinking water networks. Unaffected by pressure and temperature.<br /></p>
Ultrasonic Clamp-On Sensor NICO K1L

Clamp-on sensor for contactless flow measurement in full pipes. Clamp-on ultrasonic flow meter is ideal for retrofitting system at flow measurement places as well as for monitoring of drinking water networks. Unaffected by pressure and temperature.

Level meter programmed by a hand-held calibrator or from a computer that allows engineers to select the output to suit the application. Non-contacting level measurement. Ultrasonic.
Ultrasonic Controller VM9820 Blackbox
Level meter programmed by a hand-held calibrator or from a computer that allows engineers to select the output to suit the application. Non-contacting level measurement. Ultrasonic.
Level meter with display programmed by a hand-held calibrator or from a computer that allows engineers to select the output to suit the application. Non-contacting level measurement. Ultrasonic.<br />
Ultrasonic Controller VM9820 Blackbox with Display
Level meter with display programmed by a hand-held calibrator or from a computer that allows engineers to select the output to suit the application. Non-contacting level measurement. Ultrasonic.
Level meter instrument that combines several full-function, world-beating ultrasonic level  measurement instruments into one. Three assignable relays. Perfect for the wide range of level measurement applications in solids and liquids.
Ultrasonic Controller VM9820 Ultra 3
Level meter instrument that combines several full-function, world-beating ultrasonic level measurement instruments into one. Three assignable relays. Perfect for the wide range of level measurement applications in solids and liquids.
Non-contacting ultrasonic level control and flow measurement. Ultra 4 offers the sophistication and advanced features of the rest of the Ultra range in a compact, cost effective package and useful new features that make it even easier to set up and fine-tune. Offering as the name suggests, four alarm or control relays (3 X SPCO isolated and 1 x SPNO solid state) and a multi-functional display while loosing none of the easy set up and configuration that has made the Ultra range the natural choice for non-contacting measurement world-wide. <br /><br />Like the rest of Pulsar's 'transducer plus controller' ranges, Ultra 4 is compatiable with both dB ultrasonic and dBR radar transducers. Ultra 4 can be wither wall or fasica mounted and includes HART, Profibus and Modbus digital communications options and the convenience of on-board micro SD card slot for extended data logging. Like the rest of the Ultra range, Ultra 4 also offers built in volume calculations based on standard tank shapes as well as advanced pump control and open channel flow measurement functions.<br />
Ultrasonic Controller VM9820 Ultra 4
Non-contacting ultrasonic level control and flow measurement. Ultra 4 offers the sophistication and advanced features of the rest of the Ultra range in a compact, cost effective package and useful new features that make it even easier to set up and fine-tune. Offering as the name suggests, four alarm or control relays (3 X SPCO isolated and 1 x SPNO solid state) and a multi-functional display while loosing none of the easy set up and configuration that has made the Ultra range the natural choice for non-contacting measurement world-wide.

Like the rest of Pulsar's 'transducer plus controller' ranges, Ultra 4 is compatiable with both dB ultrasonic and dBR radar transducers. Ultra 4 can be wither wall or fasica mounted and includes HART, Profibus and Modbus digital communications options and the convenience of on-board micro SD card slot for extended data logging. Like the rest of the Ultra range, Ultra 4 also offers built in volume calculations based on standard tank shapes as well as advanced pump control and open channel flow measurement functions.
Level meter instrument that combines several full-function, world-beating ultrasonic level measurement instruments into one. Five assignable relays. Perfect for the wide range of level measurement applications in solids and liquids.
Ultrasonic Controller VM9820 Ultra 5
Level meter instrument that combines several full-function, world-beating ultrasonic level measurement instruments into one. Five assignable relays. Perfect for the wide range of level measurement applications in solids and liquids.
Ultrasonic gas flow sensor dedicated for process gas flow applications. Independent of gas density and composition to a large extend. No maintenance. No recalibration. Integrated volume correction to standard conditions using P, T measurement. No moving parts, no pressure loss.
Ultrasonic Flow Sensor VM9040 Optisonic 7000 Biogas
Ultrasonic gas flow sensor dedicated for process gas flow applications. Independent of gas density and composition to a large extend. No maintenance. No recalibration. Integrated volume correction to standard conditions using P, T measurement. No moving parts, no pressure loss.
Non-contacting ultrasonic transducers for flow applications. The dBMACH3 is the first ultrasonic transducer with zero effective blanking distance.<br />
Ultrasonic Flow Transducer VM9820 dBMach3
Non-contacting ultrasonic transducers for flow applications. The dBMACH3 is the first ultrasonic transducer with zero effective blanking distance.
Battery driven flowmeter used to measure the flow rate of homogeneous fluids. Consists of a pair of ultrasonic sensors acoustically coupled to the pipe wall and a transmitter evaluating the signals from the sensors. <br />
Ultrasonic Flowmeter VM9021P NivuSonic
Battery driven flowmeter used to measure the flow rate of homogeneous fluids. Consists of a pair of ultrasonic sensors acoustically coupled to the pipe wall and a transmitter evaluating the signals from the sensors.
Hemispheric sensor for measurement places with various geometries. For connection to NivuFlow 650 transmitters. High accurate flow measurement based on the transit time method for open channels and waters, mainly process water channels and natural water bodies. <br />
Ultrasonic Hemispheric sensor NOS V30BS
Hemispheric sensor for measurement places with various geometries. For connection to NivuFlow 650 transmitters. High accurate flow measurement based on the transit time method for open channels and waters, mainly process water channels and natural water bodies.
Non-contact ultrasonic level meter. Compact design with the latest technique in digital processing, which provides an effective filter of disturbing echoes.
Ultrasonic Level Meter VM9819 IMP Lite
Non-contact ultrasonic level meter. Compact design with the latest technique in digital processing, which provides an effective filter of disturbing echoes.
Intelligent transducers for level measurement from Pulsar.  Self-contained non-contacting ultrasonic level measurement featuring a  choice of HART or Profibus PA communications protocols.
Ultrasonic Level Meter VM9820 dBi
Intelligent transducers for level measurement from Pulsar. Self-contained non-contacting ultrasonic level measurement featuring a choice of HART or Profibus PA communications protocols.
<p>Intelligent air-ultrasonic sensor for connection to flow transmitters such as NivuFlow 750 and PCM 4 for non-contact level measurement in part filled flow measurement places.<br /></p>
Ultrasonic Level Sensor DSM

Intelligent air-ultrasonic sensor for connection to flow transmitters such as NivuFlow 750 and PCM 4 for non-contact level measurement in part filled flow measurement places.

<p>Level sensor for level measurement in combination with flow measurents. Intelligent air-ultrasonic sensor for connection to flow transmitters such as NivuFlow 750, OCM Pro and PCM for non-contact level measurement in part filled flow measurement places.<br /></p>
Ultrasonic Level Sensor OCL

Level sensor for level measurement in combination with flow measurents. Intelligent air-ultrasonic sensor for connection to flow transmitters such as NivuFlow 750, OCM Pro and PCM for non-contact level measurement in part filled flow measurement places.

Pipe sensor for use in pipelines. For full pipes. Ideal for flow measurement of process water and dirty water lines as well as hydropower pipelines.
Ultrasonic Pipe Sensor NIS RL
Pipe sensor for use in pipelines. For full pipes. Ideal for flow measurement of process water and dirty water lines as well as hydropower pipelines.
Pipe sensor for use in pipelines. For full pipes. Ideal for flow measurement of process water and dirty water lines as well as hydropower pipelines.
Ultrasonic Pipe Sensor NIS RT
Pipe sensor for use in pipelines. For full pipes. Ideal for flow measurement of process water and dirty water lines as well as hydropower pipelines.
Plug-in sensor for use in pipelines. For full pipes. To be mounted on the inside of pipe.<br />
Ultrasonic Plug-In Sensor NOS
Plug-in sensor for use in pipelines. For full pipes. To be mounted on the inside of pipe.
Rod sensor for measurement places with rectangular geometries. For connection to NivuFlow 650 transmitters. High accurate flow measurement based on the transit time method for open channels and waters, mainly process water channels and natural water bodies.<br />
Ultrasonic Rod Sensor NOS V20
Rod sensor for measurement places with rectangular geometries. For connection to NivuFlow 650 transmitters. High accurate flow measurement based on the transit time method for open channels and waters, mainly process water channels and natural water bodies.
Screw-in sensor for pressurised pipelines. For high accurate flow measurement using the transit time method according to IEC 60041 process water and high pressure lines.<br />
Ultrasonic Screw-In Sensor NOS
Screw-in sensor for pressurised pipelines. For high accurate flow measurement using the transit time method according to IEC 60041 process water and high pressure lines.
<p>Sensor used to measure the flow rate of homogeneous fluids, also non-conductive.</p>
Ultrasonic Sensor VM9021S

Sensor used to measure the flow rate of homogeneous fluids, also non-conductive.

Flowmeter for continuous measurement of actual volume flow, mass flow, flow speed, velocity of sound, gain, SNR, and diagnosis value. Installation wizard. All in one system.
Ultrasonic Sensor VM9033 Optisonic 6000
Flowmeter for continuous measurement of actual volume flow, mass flow, flow speed, velocity of sound, gain, SNR, and diagnosis value. Installation wizard. All in one system.
Flowmeter for continuous measurement of actual volume flow, mass flow, flow speed, velocity of sound, gain, SNR, and diagnosis value. Flow measurement can be done anywhere and start-up is immediate.
Ultrasonic Sensor VM9033P Optisonic 6000P
Flowmeter for continuous measurement of actual volume flow, mass flow, flow speed, velocity of sound, gain, SNR, and diagnosis value. Flow measurement can be done anywhere and start-up is immediate.
Signal converter in field - och wallmounted version. To be combined with flow sensor VM 9040 Optisonic 7000. No re-calibration needed.<br />
Ultrasonic Signal Converter GFC 300 Biogas
Signal converter in field - och wallmounted version. To be combined with flow sensor VM 9040 Optisonic 7000. No re-calibration needed.
Ultrasonic flow converter for combination with Optisonic 6000 flow sensor.
Ultrasonic Signal Converter UFC 300
Ultrasonic flow converter for combination with Optisonic 6000 flow sensor.
Ultrasonic flow converter for combination with Optisonic 6000 flow sensor.
Ultrasonic Signal Converter UFC 300P
Ultrasonic flow converter for combination with Optisonic 6000 flow sensor.
Signal converter for flow measurement of clean and homogenic liquids, also non-conductive.
Ultrasonic Signal Converter VM9021S NivuSonic
Signal converter for flow measurement of clean and homogenic liquids, also non-conductive.
<p>Sludge Transducer suited for Sludge Finder 2.</p>
Ultrasonic Sludge Transducer VM9820 Viper

Sludge Transducer suited for Sludge Finder 2.

<p>Non-contacting transducers for level, volume and flow. Reliable level, volume, open channel flow, pump control and differential measurement within liquid and solids applications. dB ultrasonic transducers utilise a low power transducer design with standard interconnecting cables - yet produce extremely high acoustic power to give exceptional results in a wide variety of challenging applications. <br /></p>
Ultrasonic Transducer VM9820 dB

Non-contacting transducers for level, volume and flow. Reliable level, volume, open channel flow, pump control and differential measurement within liquid and solids applications. dB ultrasonic transducers utilise a low power transducer design with standard interconnecting cables - yet produce extremely high acoustic power to give exceptional results in a wide variety of challenging applications.

Flow meter for pipes, open channels and water bodies. Allows high accurate flow measurements using the transit time method according to IEC 60041 for part filled and full pipes, open channels and water bodies. Up to 8 measurement paths. <br />
Ultrasonic Transmitter VM9910 NivuFlow 650
Flow meter for pipes, open channels and water bodies. Allows high accurate flow measurements using the transit time method according to IEC 60041 for part filled and full pipes, open channels and water bodies. Up to 8 measurement paths.
Transit Time Flow Measurement for clean to slightly polluted Media in Full Pipes.
Ultrasonic Transmitter VM9911 NivuFlow 600
Transit Time Flow Measurement for clean to slightly polluted Media in Full Pipes.
Robust portable flow meter for long-term monitoring of full pipes.
Ultrasonic Transmitter VM9912 NivuFlow Mobile 600
Robust portable flow meter for long-term monitoring of full pipes.
Wedge sensor for large pipes and channels. Suitable for flow measurement in part filled and full large pipelines and channels using up to 8 measurement paths.<br />
Ultrasonic Wedge Sensor NIS
Wedge sensor for large pipes and channels. Suitable for flow measurement in part filled and full large pipelines and channels using up to 8 measurement paths.
USB HART® modem. Connects to level meter dBi from Pulsar.
USB HART® Modem
USB HART® modem. Connects to level meter dBi from Pulsar.